Series 3 design and surgical isolation panels at Clínica La Sabana

Series 3 electrical design with utility permitting, maintenance of the operating-theatre isolation panels with thermographic analysis, and a power quality study.

Healthcare · Clínica La Sabana

What was needed

Operating-theatre isolation panels are the most neglected item in a clinic and the one that weighs most heavily in a licensing audit. Clínica La Sabana needed them brought up to date and, in parallel, an electrical design that required utility permitting, plus an understanding of what was happening with power quality across the facility.

Design series
Series 3
Critical areas covered
Operating theatres
Diagnostic technique
Thermography under load
Additional study
Power quality
Scope

What we did

  • Electrical design Series 3 with drawings, calculation reports and load schedules.
  • Management of the utility application through to approval.
  • Maintenance of the operating-theatre isolation panels.
  • Thermographic analysis of the panels in service, without suspending operations.
  • Power quality study of the installation.
Technical background

Why isolation panels are the critical point

In an operating theatre, the electrical system is not designed to shut off when a fault appears but to keep running and raise an alarm. That is what an isolated power system does: if a first earth fault occurs, the monitor flags it but the theatre carries on. It is the exact opposite of the logic of a domestic breaker.

That behaviour depends on the panel being in good condition and on the line isolation monitor working. And because the system is designed to tolerate the first fault without showing it, a degraded panel can go years without visible signs until the second one occurs. That is why periodic thermographic inspection, carried out with the panel under load, is the only practical way to know its real condition.

FAQ

Answers to common questions

Why is thermography done with the panel energised?
Because hot spots only appear under load. A de-energised panel looks normal even with a degraded connection. The inspection is non-invasive and does not interrupt service.
What is a Series 3 design?
It is the design category the network operator assigns according to the project's load and characteristics. It determines the level of detail required in drawings and calculation reports, and the type of application that has to be filed.
What is a power quality study for in a clinic?
To identify harmonics and disturbances that damage medical and electronic equipment. In institutions with diagnostic imaging and life-support equipment, they frequently explain failures that had seemed inexplicable.
Result

The outcome

The isolation panels were left with documented maintenance and supporting thermographic analysis, and the Series 3 design approved by the network operator.